This compact servo power module is designed to drive servo motors in conjunction
with a motion control module. Depending on which motion control module is used,
various methods of position detection can be employed.
|
|
The uniform pLINK interface serves to connect the servo power module to the
motion control module. Across this interface, all parameters and commands are transmitted,
so that there is no need to adjust any settings on the servo power module.
In addition, the complete diagnostic procedures are transmitted to the motion control module
across the pLINK interface.
|
|
This means that setting of parameters and performing diagnosis tests can be carried out on an integral basis.
|
|
The module is available in 5 power ratings with a constant rated current of 2.0 Arms
up to 20.0 Arms.
|
| |
|
| Features |
 |
|
All connections can be made by spade lugs on the front panel |
 |
|
No settings to make |
 |
|
Easy-to-enter parameters and easy-to-perform diagnosis via motion control module |
 |
|
Easy to connect to motion control module with an RJ45 cable |
 |
|
Several modules can be mounted directly adjacent to one another |
 |
|
Can be switched on and off without waiting time |
 |
|
2- and 3-phase motors can be connected direct |
 |
|
Normally open contact for driving a brake |
 |
|
Integrated brake chopper |
 |
|
Integrated line filter |
| |
|
| Technical specifications |
| Supply voltage |
3 x 400 / 480 VAC (85 VAC to 528 VAC) |
| Constant rated current |
2 Arms |
4 Arms |
8 Arms |
12 Arms |
20 Arms |
| Peak current |
5.5 A |
11 A |
22 A |
34 A |
55 A |
Switching frequency (switchable) |
16 / 32 kHz |
16 / 32 kHz |
16 / 32 kHz |
8 / 16 kHz |
8 / 16 kHz |
|
| |
| Monitoring |
 |
|
Short-circuit in the motor |
|
 |
|
Ground fault in the motor |
 |
|
Overvoltage or undervoltage state on the DC bus |
 |
|
Module temperature |
|
| |
| Technical specifications subject to change without notice. |
| |